LABOPUR 120x75 cm Laboratory Fume Hood - Class 1

HFLC11212PM+2C

Laboratory
fume hood with 1 or 2 filter
chambers. Complies with CE standards and NF X 15-211 Class 1

. For handling flammable, corrosive, and toxic substances. The fume
hood is delivered ready for use, excluding the carbon and HEPA filters.

Accés
Caisson de filtration
Option pour HEPA

payment-logo.png

PLEASE NOTE: The price does not include the REQUIRED steam detector or the filters—Pricing depends on the type of steam being treated

Compliance with NF X 15-211 Class 1

Average airflow velocity at the front (m/s) 0.5
Voltage (volts) 220–240
Airflow rate (m³/h) 180 Electrical power (watts) 35 Power supply access
panels: 4 Fan sound
power dB(A) (excluding airflow) 60.00 Digital
display of airflow and hour meter; sampling
port included. Reinforced transparent
walls on all sides providing optimal lighting of the work surface and immediate visibility of the products being handled. Optional melamine-faced work
surface

Dimensions (HxWxD mm)
: - exterior: 1160x1200x750
- interior: 935x1145x700
; weight 44 kg

Choose your access type:
two-handed access or trapezoidal access

Choose the number of filter cabinets
:
- 1
cabinet - 2 cabinets

Select the HEPA filter option if you wish to add one of the following filters:
High-efficiency HEPA filter: for cleanroom use (2 kg) [vendu séparément]
Low-efficiency HEPA filter: for handling powders and liquids (2 kg) [vendu séparément]

These fume hoods must be equipped with two activated carbon filters [vendus séparément] per filtration chamber. HEPA filters are not required.

Download the technical data sheets at the bottom of the page for more information.

SD Pack
HFLC11212PM+2C

Specific References

ean13
3577938699127
upc
377905451474

Download

Fiche technique hotte 120x75

Fiche technique hotte filtrante de laboratoire 120x75cm LABOPUR classe 1

Download (275.94KB)

Documentation hotte classe 1

Documentation gamme de hottes filtrantes de laboratoire Labopur classe 1

Download (797.11KB)